Standard Details

This is an inherent condition in the laminate caused during processing the board or assembly.

Measling or crazing that occurs as a result of an assembly process (e.g., use of press fit pins, reflow soldering, etc.) will usually not increase.

Where measles are present that violate minimum electrical clearance, additional performance testing or dielectric resistance measurements may be required considering the product performance envelope; e.g., moisture environments, low atmosphere.